Reliability and Diagnostic Accuracy of a New Vaginal Dynamometer to Measure Pelvic Floor Muscle Strength.
Clicks: 353
ID: 74161
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
64.6
/100
353 views
240 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #2 of 3 articles by views in female pelvic medicine & reconstructive surgery
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Assess the intrarater and interrater reliabilities and diagnostic accuracy of a new vaginal dynamometer to measure pelvic floor muscle (PFM) strength in incontinent and continent women.A test-retest reliability study including 152 female patients.history of urge urinary incontinence, prolapse of pelvic organ, pregnancy, previous urogynecological surgery, severe vaginal atrophy, or neurological conditions. The examination comprised digital assessment using the modified Oxford scale (MOS) and dynamometry measurements with a new prototype hand-held dynamometer. The MOS score ranges from 0 to 5: 0, no contraction; 1, flicker; 2, weak; 3, moderate; 4, good; 5, strong. Examinations were performed by a physiatrist, a physiotherapist and a midwife. The rest period between each rater measurement was 5 minutes. Assessment of intrarater and interrater reliability was calculated with the intraclass correlation coefficient.One hundred twenty-two incontinent women and 30 continent women were included. Scores between 0 and 2 in MOS were recorded in 72% of incontinent women versus 20% in continent patients (P < 0.001). Intrarater reliability of the dynamometer was 0.942 (95% confidence interval [CI], 0.920-0.958) and the interrater reliability was 0.937 (95% CI, 0.913-0.954). The analysis of variance analysis showed significant differences in PFM strength across digital assessment categories. The post-hoc analysis showed statistical differences between adjacent categories of MOS 1-2 and 2-3. The diagnostic accuracy showed an area under the curve of 0.82 (95% C,: 0.75-0.89), 0.87 (95% CI, 0.81-0.92), and 0.83 (95% CI, 0.77-0.90) for the physiatrist, midwife, and physiotherapist, respectively.The results obtained show a good reliability and validity of this new vaginal dynamometer to quantify PFM strength.
| Reference Key |
romerocullers2019reliabilityfemale
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Romero-Cullerés, Georgia;Peña-Pitarch, Esteban;Jané-Feixas, Cecilia;Vilaseca-Grané, Anna;Montesinos, Jesus;Arnau, Anna; |
| Journal | female pelvic medicine & reconstructive surgery |
| Year | 2019 |
| DOI |
10.1097/SPV.0000000000000796
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.