Simultaneous phase-inversion and imprinting based sensor for highly sensitive and selective detection of bisphenol A.

Clicks: 309
ID: 74031
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #66 of 391 articles by views in Talanta

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 391 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
A novel recognition element of molecularly imprinted films (MIFs) was synthesized by wet phase inversion (WPI) on the surface of Ti/TiO electrode for highly selective and sensitive electrochemical detection of bisphenol A (BPA). The Ti/TiO/MIFs sensor was constructed by casting the precursor poly(acrylonitrile-co-acrylic acid) (p(AN-co-AA)) in dimethyl sulfoxide containing template molecule BPA onto the electrode and then immersing into water, resulting in simultaneous p(AN-co-AA) precipitation and BPA imprinting via the facile WPI. The imprinted sites could selectively rebind BPA through hydrogen bonding and hence lead to the equalizing current increase in amperometric detection, by which the BPA could be sensed electrochemically. Accordingly, the Ti/TiO/MIFs sensor offered a favorable linearity within the wide range over five orders of magnitude (4.4nM-0.13mM), and a low detection limit down to 1.3nM. Excellent recognition selectivity for BPA was also attained over its analogues. Furthermore, this sensor was successfully applied to detect BPA in seawater and paper cup samples, and high recoveries were 86-110% with low relative standard deviations of 1.3-3.2%. By using BPA as a model, the MIFs-based method may provide a facile, rapid, and cost-effective way for ultrasensitive electrochemical measurements of various targeted compounds with good applicability to WPI.
Reference Key
yang2018simultaneoustalanta Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Yang, Qian;Wu, Xiaqing;Peng, Hailong;Fu, Longwen;Song, Xingliang;Li, Jinhua;Xiong, Hua;Chen, Lingxin;
Journal Talanta
Year 2018
DOI
S0039-9140(17)30904-9
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.