Simultaneous determination of bisphenol A and its chlorinated derivatives in human plasma: Development, validation and application of a UHPLC–MS/MS method
Clicks: 228
ID: 73553
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
228 views
23 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #266 of 409 articles by views in Chemosphere
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 409 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Bisphenol A (BPA) is a well-known ubiquitous chemical found in polycarbonate, polysulfone and epoxy resins, used in mass production for many consumer products. BPA exhibits endocrine disruptor properties that can potentially induce adverse health effects. In aquatic environments, it can react with chlorine to produce chlorinated derivatives (ClxBPAs). ClxBPAs exhibit oestrogenic activity 10 to 105 times higher than BPA itself. Assessing human exposure to endocrine disrupting chemicals is mandatory to assess health risk. Blood, as well as urine matrix, are commonly used to perform human biomonitoring. We therefore developed, fully validated and applied a method based on Ultra High Performance Liquid Chromatography couples to a Triple Quad Mass Spectrometer to determine BPA, monochlorobisphenol A (MCBPA), dichlorobisphenol A (DCBPA), trichlorobisphenol A (TCBPA) and tetrachlorobisphenol A (TTCBPA) in human blood plasma. The European Medicines Agency guidelines for bioanalytical method validation have been applied. Precision and trueness of the method were <15% at medium and high levels of quality control and <20% at the limits of quantification (LOQs). The LOQs were settled at 0.1 ng/mL for BPA, 0.02 ng/mL for TTCBPA and 0.005 ng/mL for MCBPA, DCBPA, and TCBPA. The analytical method was applied to ten patients suffering from end stage renal disease. BPA was quantified in all ten patients while MCBPA, DCBPA and TTCBPA were determined in three and TCBPA in four. In conclusion, we have successfully developed a highly sensitive method to determine BPA and ClxBPAs in human plasma. Thanks to this method, for the first time, we could demonstrate ClxBPAs occurrence in human blood.
| Reference Key |
cambien2020simultaneouschemosphere
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Cambien, G. |
| Journal | Chemosphere |
| Year | 2020 |
| DOI |
10.1016/j.chemosphere.2019.125236
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.