Fluorometric determination of mercury(II) using positively charged gold nanoparticles, DNA-templated silver nanoclusters, T-Hg(II)-T interaction and exonuclease assisted signal amplification.
Clicks: 238
ID: 73259
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
72.6
/100
238 views
194 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #57 of 75 articles by views in Mikrochimica acta
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
The authors describe a method for detection of Hg by using positively charged gold nanoparticles ((+)AuNPs) as a quencher of the fluorescence of DNA-capped silver nanoclusters (DNA-AgNCs) which are negatively charged. In the presence of Hg, a DNA duplex is formed through T-Hg-T coordination chemistry. The duplex can be digested by exonuclease III to form smaller DNA fragments. This leads to the release of the AgNCs and the recovery of fluorescence, best measured at excitation/emission wavelengths of 460/530 nm. The (+)AuNPs and Hg are also released and can be reused for target recycling signal amplification. Based on these findings, a method is worked out for the determination of Hg that works in the 5.0 pM to 10 nM concentration range and has a detection limit as low as 2.3 pM. It is highly selective because of the highly specific formation of T-Hg-T bonds. Graphical abstract By using ultrastable and positively charged gold nanoparticles as fluorescence quenchers and exonuclease assisted signal amplification, a method is developed for the sensitive and selective detection of Hg in water samples.
| Reference Key |
ma2019fluorometricmikrochimica
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Ma, Haiyan;Xue, Ning;Wu, Shujie;Li, Zongbing;Miao, Xiangmin; |
| Journal | Mikrochimica acta |
| Year | 2019 |
| DOI |
10.1007/s00604-019-3388-7
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.