Voltammetric determination of cadmium(II), lead(II) and copper(II) with a glassy carbon electrode modified with silver nanoparticles deposited on poly(1,8-diaminonaphthalene).

Clicks: 276
ID: 73256
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #49 of 75 articles by views in Mikrochimica acta

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
A glassy carbon (GC) electrode was modified with poly(1,8-diaminonaphthalene) (p-1,8-DAN) that was coated with silver nanoparticles (Ag NPs) (size: 10.0-60.0 nm by TEM) by electrodeposition process using cyclic voltammetry (CV) technique. The resulting nanocomposite was characterized by FE-SEM, AFM, EDX, XPS, TEM and XRD. The surface area and the electrochemical characteristics of the electrode were investigated by CV and square wave voltammetry (SWV) techniques, and the probe preparation conditions were optimized. The electrode was used for individual and simultaneous determination of the heavy metal ions cadmium(II) (Cd), lead(II) (Pb) and copper(II) (Cu) in water samples by square wave anodic stripping voltammetry (ASV) using scan rate 0.005 V. s. The probe showed well separated anodic stripping peaks for Cd, Pb, and Cu. Attractive features of the method include (a) peak voltages of -1.02, -0.78 and - 0.32 V (vs. Ag/AgCl) for the three ions, and (b) low limits of detection (19, 30 and 6 ng.L, respectively. The electrode can also detect zinc(II) (Zn) and mercury(II) (Hg), typically at -1.36 V and + 0.9, respectively. Graphical abstract Schematic presentation of simultaneous electrochemical determination of Pb, Cd, and Cu at a poly(1,8-diaminonaphthalene)-modified glassy carbon electrode coated with silver nanoparticles.
Reference Key
hassan2019voltammetricmikrochimica Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Hassan, Khalid M;Elhaddad, Ghada M;AbdelAzzem, Magdi;
Journal Mikrochimica acta
Year 2019
DOI
10.1007/s00604-019-3552-0
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.