Development of a paper-based method to detect Hg in waste water using iturin from Bacillus subtilis.

Clicks: 293
ID: 73252
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #30 of 81 articles by views in Applied microbiology and biotechnology

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Colorimetric, fluorescence, and paper-based method were developed to measure the Hg level in water using iturin A, a lipopeptide produced by Bacillus subtilis. Firstly, iturin was used to synthesize highly stable and uniformly sized silver nanoparticles (AgNPs). Secondly, the iturin-AgNPs were found to be highly selective and sensitive to Hg. The absorbance of the reaction system showed a good linear correlation with the Hg concentration from 0.5 to 5 mg/L at 450 nm in the UV-Vis spectroscopy detection with the limit of detection (LOD) of 0.5 mg/L. When the reaction system was detected by fluorescence measurement, a good linear relationship was found between the fluorescence intensity and Hg concentration from 0.05 to 0.5 mg/ at 415 nm with the LOD of 0.05 mg/L. Lastly, a paper-based detection method was developed. The developed method was successfully used to detect Hg in contaminated polluted waters and showed acceptable results in terms of sensitivity, selectivity and stability. The paper-based method could distinguish Hg at levels higher than 0.05 mg/L, thereby meeting the guidelines of the effluent quality standard for industries (0.05 mg/L). In summary, this method can be used daily by various industries to monitor the Hg level in effluent water.
Reference Key
zhao2019developmentapplied Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Zhao, Xixi;Ai, Chongyang;Li, Zhenzhu;Xu, Xiaoguang;Zhao, Haobin;Yan, Lu;Jiang, Chunmei;Shao, Dongyan;Shi, Junling;
Journal Applied microbiology and biotechnology
Year 2019
DOI
10.1007/s00253-019-10109-5
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.