Three-dimensional microfluidic tape-paper-based sensing device for blood total bilirubin measurement in jaundiced neonates.

Clicks: 299
ID: 72394
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #12 of 18 articles by views in lab on a chip

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
More than 60% newborns experience hyperbilirubinemia and jaundice within the initial week after birth due to the accumulation of total bilirubin in blood. Left untreated high levels of bilirubin may result in brain impairment. Simple, fast, accurate, low-cost and timely point-of-care (POC) analysis of total bilirubin is an unmet need especially in resource-limited areas. This work introduces a novel sensing device, named a "tape-paper sensor", capable of separating plasma from whole blood and measuring total bilirubin by a colorimetric diazotization method. The tape-paper sensing method overcomes non-homogeneous color distribution caused by the "coffee stain" effect, which improves the accuracy of colorimetric evaluation on paper-based analytical devices. The level of hemolysis in the plasma extracted by the device is evaluated, confirming no interference in the detection of total bilirubin. The accuracy of the tape-paper sensing approach for neonatal blood sample measurement is verified by comparison with the hospital pathology laboratory method. The small volume of samples and reagents, minimal equipment (an office scanner), fast detection (<10 min) and low fabrication cost (∼A$ 0.6) reveal the suitability of the device for POC use and in resource-limited settings. The tape-paper sensor is a low-cost, fast, and user-friendly device for measurement of blood total bilirubin levels in neonatal jaundice diagnostics.
Reference Key
tan2019threedimensionallab Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Tan, Weirui;Zhang, Liyuan;Doery, James C G;Shen, Wei;
Journal lab on a chip
Year 2019
DOI
10.1039/c9lc00939f
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.