Noise levels of dental equipment used in dental college of Damascus University

Clicks: 460
ID: 71484
2014
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #1 of 5 articles by views in dental research journal

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Background: In dental practical classes, the acoustic environment is characterized by high noise levels in relation to other teaching areas. The aims of this study were to measure noise levels produced during the different dental learning clinics, by equipments used in dental learning areas under different working conditions and by used and brand new handpieces under different working conditions. Materials and Methods: The noise levels were measured by using a noise level meter with a microphone, which was placed at a distance of 15 cm from a main noise source in pre-clinical and clinical areas. In laboratories, the microphone was placed at a distance of 15 cm and another reading was taken 2 m away. Noise levels of dental learning clinics were measured by placing noise level meter at clinic center. The data were collected, tabulated and statistically analyzed using t-tests. Significance level was set at 5%. Results: In dental clinics, the highest noise was produced by micro motor handpiece while cutting on acrylic (92.2 dB) and lowest noise (51.7 dB) was created by ultrasonic scaler without suction pump. The highest noise in laboratories was caused by sandblaster (96 dB at a distance of 15 cm) and lowest noise by stone trimmer when only turned on (61.8 dB at a distance of 2 m). There was significant differences in noise levels of the equipment′s used in dental laboratories and dental learning clinics (P = 0.007). The highest noise level recorded in clinics was at pedodontic clinic (67.37 dB). Conclusions: Noise levels detected in this study were considered to be close to the limit of risk of hearing loss 85 dB.
Reference Key
qsaibati2014noisedental Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Qsaibati, Mhd. Loutify;Ibrahim, Ousama;
Journal dental research journal
Year 2014
DOI
DOI not found
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.