Alfenol patch-, galfenol patch- and galfenol paint-based torque sensor characterization studies

Clicks: 200
ID: 71039
2019
Article Quality & Performance Metrics
Overall Quality Improving Quality
0.0 /100
Combines engagement data with AI-assessed academic quality
AI Quality Assessment
Not analyzed
Abstract
Alfenol (Fe-Al) and Galfenol (Fe-Ga) are iron-based structural magnetostrictive alloys that, for compositions of ∼81% iron, are increasingly being used in sensing, actuating, and energy harvesting devices [Park et al., AIP Advances 6(5), 056221 (2016)]. Recent improvements in the development of magnetostrictive materials using the deformation processing methods of rolling to produce highly textured thin sheet [Park et al., AIP Advances 6(5), 056221 (2016)] and ball milling to produce (001)-oriented micron-size flakes [S. M. Na, J. Galuardi, and A. B. Flatau, IEEE Transactions on Magnetics 53(11), 1–4 (2017)] provide the opportunity to develop a non-contact torque sensor. Torque-induced shear forces at the surface of a shaft lead to a measurable change in the flux passing through the air above the surface of a shaft to which a magnetostrictive layer has been bonded. The current study builds on prior work which demonstrated that torque influenced the magnitude of magnetic flux in the air gaps located between a piece of Galfenol and the rest of a magnetic circuit [Raghunath et al., Proceedings of the ASME, 2013]. The current work overcomes limitations of the prior work. This work demonstrates that using a magnetostrictive layer made of a patch of Alfenol, an alloy that is less expensive, more ductile, and less magnetostrictive than Galfenol, but has almost the same saturation magnetization of ∼1.5T, slightly outperformed the patches made of Galfenol. Additional contributions of the present work include a first look at the application to a shaft of an epoxy-based paint containing micron-sized flakes of (001)-oriented Galfenol, and a comparison of square and ring-shaped patches (aspect ratios of 1 and of ∼4). Data are presented from quasi-static testing and from dynamic tests at rotational rates of up to 1000 rpm.
Reference Key
muller2019alfenolaip Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Muller, Brooks;Order, Michael N. Van;Na, Suok-Min;Flatau, Alison B.;
Journal aip advances
Year 2019
DOI
DOI not found
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.