Quantitative bioluminometric method for DNA-based species/varietal identification in food authenticity assessment.
Clicks: 362
ID: 70896
2012
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
63.1
/100
362 views
244 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #33 of 850 articles by views in Journal of agricultural and food chemistry
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 850 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
A method is reported for species quantification by exploiting single-nucleotide polymorphisms (SNPs). These single-base changes in DNA are particularly useful because they enable discrimination of closely related species and/or varieties. As a model, quantitative authentication studies were performed on coffee. These involved the determination of the percentage of Arabica and Robusta species based on a SNP in the chloroplastic trnL(UAA)-trnF(GAA) intraspacer region. Following polymerase chain reaction (PCR), the Robusta-specific and Arabica-specific fragments were subjected to 15 min extension reactions by DNA polymerase using species-specific primers carrying oligo(dA) tags. Biotin was incorporated into the extended strands. The products were captured in streptavidin-coated microtiter wells and quantified by using oligo(dT)-conjugated photoprotein aequorin. Aequorin was measured within 3 s via its characteristic flash-type bioluminescent reaction that was triggered by the addition of Ca(2+). Because of the close resemblance between the two DNA fragments, during PCR one species serves as an internal standard for the other. The percentage of the total luminescence signal obtained from a certain species was linearly related to the percent content of the sample with respect to this species. The method is accurate and reproducible. The microtiter well-based assay configuration allows high sample throughput and facilitates greatly the automation.
| Reference Key |
trantakis2012quantitativejournal
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Trantakis, Ioannis A;Christopoulos, Theodore K;Spaniolas, Stelios;Kalaitzis, Panagiotis;Ioannou, Penelope C;Tucker, Gregory A; |
| Journal | Journal of agricultural and food chemistry |
| Year | 2012 |
| DOI |
10.1021/jf203531h
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.