Low-Input Estimation of Site-Specific Lime Demand Based on Apparent Soil Electrical Conductivity and In Situ Determined Topsoil pH.

Clicks: 389
ID: 70690
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #263 of 1,694 articles by views in sensors

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 1,694 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Site-specific liming helps increase efficiency in agricultural production. For adequate determination of the lime demand, a combination of apparent soil electrical conductivity (EC) and topsoil pH can be used. Here, it was hypothesized that this can also be done at low-input level. Field measurements using the EM38 MK I (Geonics, Canada) were conducted on three experimental sites in north Germany in 2011. The topsoil pH was measured based on two approaches: on the field using a handheld pH meter (Spectrum-Technologies Ltd., Bridgend, UK) with a flat electrode (in situ), and in the lab using standard equipment (ex situ). Both soil EC (0.4-35.9 mS m) and pH (5.13-7.41) were heterogeneously distributed across the sites. The same was true of the lime demand (-1.35-4.18 Mg ha). There was a significant correlation between in situ and ex situ determined topsoil pH (r = 0.89; < 0.0001). This correlation was further improved through non-linear regression (r = 0.92; < 0.0001). Thus, in situ topsoil pH was found suitable for map-overlay with EC to determine the site-specific lime demand. Consequently, the hypothesis could be confirmed: The combined use of data from EM38 and handheld pH meters is a promising low-input approach that may help implement site-specific liming in developing countries.
Reference Key
von-cossel2019lowinputsensors Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal sensors
Year 2019
DOI
E5280
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.