Low-Input Estimation of Site-Specific Lime Demand Based on Apparent Soil Electrical Conductivity and In Situ Determined Topsoil pH.

Clicks: 324
ID: 70690
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #299 of 1,694 articles by views in sensors

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 1,694 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Site-specific liming helps increase efficiency in agricultural production. For adequate determination of the lime demand, a combination of apparent soil electrical conductivity (EC) and topsoil pH can be used. Here, it was hypothesized that this can also be done at low-input level. Field measurements using the EM38 MK I (Geonics, Canada) were conducted on three experimental sites in north Germany in 2011. The topsoil pH was measured based on two approaches: on the field using a handheld pH meter (Spectrum-Technologies Ltd., Bridgend, UK) with a flat electrode (in situ), and in the lab using standard equipment (ex situ). Both soil EC (0.4-35.9 mS m) and pH (5.13-7.41) were heterogeneously distributed across the sites. The same was true of the lime demand (-1.35-4.18 Mg ha). There was a significant correlation between in situ and ex situ determined topsoil pH (r = 0.89; < 0.0001). This correlation was further improved through non-linear regression (r = 0.92; < 0.0001). Thus, in situ topsoil pH was found suitable for map-overlay with EC to determine the site-specific lime demand. Consequently, the hypothesis could be confirmed: The combined use of data from EM38 and handheld pH meters is a promising low-input approach that may help implement site-specific liming in developing countries.
Reference Key
von-cossel2019lowinputsensors Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors von Cossel, Moritz;Druecker, Harm;Hartung, Eberhard;
Journal sensors
Year 2019
DOI
E5280
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.