Simultaneous determination of 44 pharmaceutically active compounds in water samples using solid-phase extraction coupled with ultra-performance liquid chromatography-tandem mass spectrometry.
Clicks: 343
ID: 70146
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
30.0
/100
343 views
65 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #19 of 90 articles by views in Analytical and bioanalytical chemistry
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
This study examines an improved and simplified method for solid-phase extraction (SPE), which offers rapid and accurate determination and identification of 44 pharmaceutically active compounds using ultra-performance liquid chromatography (UPLC) and tandem mass spectrometry (MS/MS). The common active compounds include four macrolides, seventeen sulfonamides, four quinolones, chloramphenicol, eight β-lactams, four tetracyclines, lincomycin, amantadine, 4-acetamidophenol, phenylbutazone, trimethoprim, clenbuterol, and hydrocortisone in water samples. We optimized crucial parameters of MS/MS, UPLC, and SPE and studied the matrix effect related to the modified analytical process from water samples. The matrix-matched calibration curves were accomplished at seven concentration levels and a satisfactory linear relationship (r > 0.994) was observed within the range of 0.1-500 ng/mL. Results show varying limits of detection (0.0111-0.966 ng/L for different analytes based on signal-to-noise (S/N) = 3) and limits of quantitation (0.0382-3.26 ng/L). Recoveries of the spiked samples ranged from 75.7 to 108% with relative standard deviation lower than 9.6%. The proposed method was successfully applied to the analysis of real samples.
| Reference Key |
xue2019simultaneousanalytical
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Xue, Ming;Wu, Haocheng;Liu, Shaoying;Huang, Xihui;Jin, Quan;Ren, Ren; |
| Journal | Analytical and bioanalytical chemistry |
| Year | 2019 |
| DOI |
10.1007/s00216-019-02229-8
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.