Simultaneous determination of 44 pharmaceutically active compounds in water samples using solid-phase extraction coupled with ultra-performance liquid chromatography-tandem mass spectrometry.

Clicks: 343
ID: 70146
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #19 of 90 articles by views in Analytical and bioanalytical chemistry

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
This study examines an improved and simplified method for solid-phase extraction (SPE), which offers rapid and accurate determination and identification of 44 pharmaceutically active compounds using ultra-performance liquid chromatography (UPLC) and tandem mass spectrometry (MS/MS). The common active compounds include four macrolides, seventeen sulfonamides, four quinolones, chloramphenicol, eight β-lactams, four tetracyclines, lincomycin, amantadine, 4-acetamidophenol, phenylbutazone, trimethoprim, clenbuterol, and hydrocortisone in water samples. We optimized crucial parameters of MS/MS, UPLC, and SPE and studied the matrix effect related to the modified analytical process from water samples. The matrix-matched calibration curves were accomplished at seven concentration levels and a satisfactory linear relationship (r > 0.994) was observed within the range of 0.1-500 ng/mL. Results show varying limits of detection (0.0111-0.966 ng/L for different analytes based on signal-to-noise (S/N) = 3) and limits of quantitation (0.0382-3.26 ng/L). Recoveries of the spiked samples ranged from 75.7 to 108% with relative standard deviation lower than 9.6%. The proposed method was successfully applied to the analysis of real samples.
Reference Key
xue2019simultaneousanalytical Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Xue, Ming;Wu, Haocheng;Liu, Shaoying;Huang, Xihui;Jin, Quan;Ren, Ren;
Journal Analytical and bioanalytical chemistry
Year 2019
DOI
10.1007/s00216-019-02229-8
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.