Adaptive Backstepping Control with Online Parameter Estimator for a Plug-and-Play Parallel Converter System in a Power Switcher
Clicks: 261
ID: 69772
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
76.5
/100
261 views
214 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #78 of 220 articles by views in energies
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 220 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
This study aims to address the inherent uncertainty in plug loads and load extraction, distributed generation, and the inevitable circulating current in a parallel structure. Therefore, in this paper, an adaptive backstepping control scheme with an online parameter estimator (OPE) for a plug-and-play parallel converter system in a four-port power switcher is proposed. The adaptive backstepping control method was designed in the dq0 coordinate system to suppress the circulating current in the zero-component; the circulating current can be suppressed by using an embedded algorithm and omitting the extra controller. An adaptive update law was designed to weaken the influence of the arbitrary plug and extraction operations in the DC and AC buses to realize the plug-and-play function. The transient tracking performance is governed by the limitation of maximum total errors in the voltage and current. As a result, the settling times of the voltage, current, and power decreased. Additionally, to further improve the system robustness, an online inductance and resistance estimator was established using an optimal algorithm that solves the weighted least squares problem. In the estimator, there are no additional voltage and current sensors needed, and the mean squared error (MSE) of the estimation can be minimized. Simulation studies on a two-converter parallel system with a plug-and-play function were conducted using MATLAB/SIMULINK (R2018b, MathWorks, Natick, MA, USA) to verify the effectiveness of the proposed adaptive backstepping control strategy. The results show that this strategy improves system performance over that of a system with unbalanced parameters among a parallel structure with AC and DC system disturbances caused by arbitrary plug and extraction operations.
| Reference Key |
guo2018adaptiveenergies
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Guo, Chujia;Zhang, Aimin;Zhang, Hang;Zhang, Lei; |
| Journal | energies |
| Year | 2018 |
| DOI |
DOI not found
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.