Moving beyond LDL-C: incorporating lipoprotein particle numbers and geometric parameters to improve clinical outcomes

Clicks: 315
ID: 6850
2010
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #44 of 242 articles by views in research reports in clinical cardiology

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 242 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Moving beyond LDL-C: incorporating lipoprotein particle numbers and geometric parameters to improve clinical outcomes Thomas Dayspring1, Tara Dall2, Majed Abuhajir31North Jersey Institute of Menopausal Lipidology, Wayne, NJ, USA; 2Advanced Lipidology, Delafield, WI, USA; 3Clinical Trials, Columbia-St Mary’s Cancer Center, Milwaukee, WI, USAAbstract: Lipoproteins are complex protein-enwrapped particles which traffic hydrophobic lipids and other molecules between tissues in plasma. Under a variety of pathological states, specific lipoproteins trafficking sterols, phospholipids, and fatty acids enter arterial walls enhancing a maladaptive inflammatory response resulting in atherogenesis. Several lipoprotein particle geometric parameters are now readily available from the laboratory. Such measurements beyond standard lipid concentrations can be used to better understand both the link between atherogenesis and the trafficking patterns of lipoproteins. Often, the various laboratory indices, especially standard particle lipid concentrations versus lipoprotein particle parameters, seem to conflict or exhibit discordance and thus confuse the patient and the provider. By using readily available (but often misunderstood) particle geometric parameters from two patients, we have attempted to illustrate that by properly utilizing the newer assays, very discordant standard lipid concentrations and lipoprotein laboratory parameters can be present in two specific patients and demonstrate how the newer parameters can aid the clinicians in performing better risk assessment and treatment decisions.Keywords: lipoproteins, HDL-cholesterol, LDL-cholesterol, LDL particle number, HDL particle number, LDL composition, LDL size
Reference Key
thomas2010movingresearch Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Thomas Dayspring;Tara Dall;Majed Abuhajir and
Journal research reports in clinical cardiology
Year 2010
DOI
10.2147/RRCC.S14825
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.