Combined spinal-epidural analgesia in labour: its effects on delivery outcome
Clicks: 680
ID: 68430
2016
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
72.1
/100
680 views
515 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #1 of 6 articles by views in revista brasileira de anestesiologia
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
ABSTRACT BACKGROUND AND OBJECTIVES: Combined spinal-epidural (CSE) has become an increasingly popular alternative to traditional labour epidural due to its rapid onset and reliable analgesia provided. This was a prospective, convenient sampling study to determine the effects of CSE analgesia on labour outcome. METHODS: One hundred and ten healthy primigravida parturients with a singleton pregnancy of ≥37 weeks gestation and in the active phase of labour were studied. They were enrolled to the CSE (n = 55) or Non-CSE (n = 55) group based on whether they consented to CSE analgesia. Non-CSE parturients were offered other methods of labour analgesia. The duration of the first and second stage of labour, rate of instrumental vaginal delivery and emergency cesarean section, and Apgar scores were compared. RESULTS: The mean duration of the first and second stage of labour was not significantly different between both groups. Instrumental delivery rates between the groups were not significantly different (CSE group, 11% versus Non-CSE group, 16%). The slightly higher incidence of cesarean section in the CSE group (16% versus 15% in the Non-CSE group) was not statistically significant. Neonatal outcome in terms of Apgar score of less than 7 at 1 and 5 min was similar in both groups. CONCLUSION: There were no significant differences in the duration of labour, rate of instrumental vaginal delivery and emergency cesarean section, and neonatal outcome in parturients who received compared to those who did not receive CSE for labour analgesia.
| Reference Key |
singh2016combinedrevista
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Singh, Suneet Kaur Sra Charanjit;Yahya, Nurlia;Misiran, Karis;Masdar, Azlina;Nor, Nadia Md;Yee, Lee Choon; |
| Journal | revista brasileira de anestesiologia |
| Year | 2016 |
| DOI |
DOI not found
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.