The use of imidazolium ionic liquid/copper complex as novel and green catalyst for chemiluminescent detection of folic acid by Mn-doped ZnS nanocrystals.
Clicks: 462
ID: 684
2014
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Popular Article
72.8
/100
462 views
330 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
PopularRanked #8 of 116 articles by views in spectrochimica acta part a, molecular and biomolecular spectroscopy
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
A novel chemiluminescence (CL) method using water-soluble Mn-doped ZnS quantum dots (QDs) as CL emitter is proposed for the chemiluminometric determination of folic acid in pharmaceutical formulation. Water-soluble Mn-doped ZnS QDs were synthesized by using L-cysteine as stabilizer in aqueous solutions. The nanoparticles were structurally and optically characterized by X-ray powder diffraction (XRD), dynamic light scattering (DLS), Fourier transform infrared spectroscopy (FTIR), UV-Vis absorption spectroscopy and photoluminescence (PL) emission spectroscopy. The CL of ZnS QDs induced by directly chemical oxidation and its ionic liquid-sensitized effect in aqueous solution were then investigated. It was found that oxidants, especially hydrogen peroxide, could directly oxidize ZnS QDs to produce weak CL emission in basic conditions. In the presence of 1,3-dipropylimidazolium bromide/copper a drastic light emission enhancement is observed, related to a strong interaction between Cu(2+) and the imidazolium ring. Therefore, a new CL analysis system was developed for the determination of folic acid. Under the optimum conditions, there is a good linear relationship between the relative CL intensity and the concentration of folic acid in the range of 1×10(-9)-1×10(-)(6) M of folic acid with a correlation coefficient (R(2)) of 0.9991. The limit of detection of this system was found to be 1×10(-)(10) M. This method is not only simple, sensitive and low cost, but also reliable for practical applications.
| Reference Key |
azizi2014the
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Azizi, Seyed Naser;Shakeri, Parmis;Chaichi, Mohammad Javad;Bekhradnia, Ahmadreza;Taghavi, Mehdi;Ghaemy, Mousa; |
| Journal | spectrochimica acta part a, molecular and biomolecular spectroscopy |
| Year | 2014 |
| DOI |
10.1016/j.saa.2013.11.036
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.