Effect and Safety of Labor Epidural Analgesia with Intermittent Boluses of 0.1% Bupivacaine with Fentanyl on Fetal and Maternal Outcomes and Wellbeing.

Clicks: 396
ID: 68393
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #1 of 3 articles by views in anesthesia, essays and researches

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Labor analgesia has been shown to have few undesirable effects on the course and outcome of the labor as well as on the fetal well-being.This study aims to assess neonatal outcome following lumbar epidural analgesia with intermittent boluses of 0.1% bupivacaine with fentanyl. The secondary objectives included assessment of maternal analgesia, complications, and outcome of labor.Prospective observational study conducted at a tertiary care teaching institute.Sixty-three patients for labor epidural analgesia were recruited. Epidural catheter was inserted in L4-L5 or L3-L4 interspace. After confirmation of the position of catheter, 3 mL of 0.5% bupivacaine with 20 μg of fentanyl made to 15 mL was administered. After 30 min, efficacy of analgesia was assessed by visual analog scale (VAS). The same bolus dose was repeated after 90 min if the patient complained of pain. A maximum of five top-up doses were allowed.Mean and standard deviation, number and percentage.After 30 min of first bolus dose, 93.3% had VAS score of <4. More than 90% patients had adequate analgesia till 4 epidural bolus. During contraction stress test, only two fetuses had late deceleration. About 80% and 98.3% newborns had Apgar of >7 at 1 and 5 min, respectively. Umbilical cord blood pH was ≥7.1 in 98.3% neonates with base excess of >-12. 58.3% delivered normally, 23.3% had instrumental vaginal delivery, and 18.3% required cesarean section.Lumbar epidural analgesia with 0.1% bupivacaine with fentanyl provides optimal neonatal outcome, labor analgesia, and labor outcome.
Reference Key
kesavaneffectanesthesia Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Kesavan, Rajesh;Rajan, Sunil;Kumar, Lakshmi;
Journal anesthesia, essays and researches
Year Year not found
DOI
10.4103/aer.AER_168_18
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.