A dq-Domain Impedance Measurement Methodology for Three-Phase Converters in Distributed Energy Systems

Clicks: 281
ID: 68346
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #63 of 220 articles by views in energies

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 220 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
A distributed energy system (DES) using controlled power electronics converters delivers power to loads, via conventional, as well as a number of renewable, energy sources. However, stability concerns retard the integration of power electronics converters into an existing DES. Therefore, due to the high penetration of power converters, the overall network analysis of DES is becoming increasingly difficult. Impedance-based DES modeling emerged as an effective technique as it reduces the system into source and load subsystems and offers easier analysis of the dynamic interactions between them. These models can be obtained using either analytical calculations, simulations, or experimental measurements. In this work, firstly, a line-to-line current injection technique is used for the measurement of alternating current (AC) impedances. Since it requires repeated injections, a d q -domain impedance measurement methodology based upon a set of independent perturbations and measurements is proposed. The perturbation is injected via a sweep signal which is preprocessed by the digital signal processor (DSP) prior to injection. The d q reference frame is synchronized with the three-phase AC system using a low-bandwidth phase-locked loop (PLL). The close matching of impedance parameters measured in simulation using the proposed approach with those obtained using analytical expressions and the line-to-line current injection technique verifies the effectiveness of the approach. Furthermore, the method was also implemented experimentally, and the close matching of the results with the analytical and simulation results validates the overall modeling and measurement procedure.
Reference Key
saad2018aenergies Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Saad, Muhammad;Ali, Husan;Liu, Huamei;Khan, Shahbaz;Zaman, Haider;Khan, Bakht Muhammad;Kai, Du;Yongfeng, Ju;
Journal energies
Year 2018
DOI
DOI not found
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.