Central aortic blood pressure and augmentation index: comparison between Vasotens® and SphygmoCor® technology
Clicks: 254
ID: 6832
2012
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Popular Article
80.9
/100
254 views
206 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
PopularRanked #147 of 242 articles by views in research reports in clinical cardiology
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 242 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Central aortic blood pressure and augmentation index: comparison between Vasotens® and SphygmoCor® technology Anatoliy N Rogoza,1 Aleksandr A Kuznetsov21Cardiology Research Complex, Moscow, Russian Federation; 2Therapy Research Institute, Siberian branch of Russian Academy of Medical Science, Novosibirsk, Russian FederationIntroduction: The aim of this study is the comparison of Vasotens® technology as used in a device with an oscillometric method of blood pressure measurement (BPLab, Petr Telegin Ltd, Nizhny Novgorod, Russian Federation) against the validated tonometric system (SphygmoCor®, AtCor Medical Pty Ltd, West Ryde, Australia).Methods: The examinations were carried out in two medical centers. Exclusion criteria included atrial fibrillation, severe cardiac anomalies, heart failure, arrhythmia, decompensated diabetes, the presence of an artificial pacemaker, pregnancy, and BMI > 30. Overall, 160 patients and healthy volunteers were examined. Central aortic systolic blood pressure (aSBP) and augmentation index (aAIx) were obtained by means of applanation tonometry and the oscillometric method was compared.Results: aSBP and aAIx measured using the BPLab device equates significantly with the same parameters measured by SphygmoCor.Conclusion: This finding allows the recommendation of Vasotens technology, which can be used with the 24-hour BPLab monitoring system for wide clinical use.Keywords: central aortic blood pressure, augmentation index, validation, Vasotens®, BPLab®
| Reference Key |
anatoliy2012centralresearch
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Anatoliy N Rogoza;Aleksandr A Kuznetsov and |
| Journal | research reports in clinical cardiology |
| Year | 2012 |
| DOI |
10.2147/RRCC.S30994
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.