MoC combined with carbon material nanosphere as an electrochemiluminescence super-enhancer and antibody label for ultrasensitive detection of cardiac troponin I.
Clicks: 248
ID: 68301
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
74.2
/100
248 views
192 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #51 of 85 articles by views in Biosensors & bioelectronics
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
To sensitively detect cardiac troponin I (cTnI), a novel electrochemiluminescence (ECL) immunosensor was constructed on the basis of the core-shell MoC combined with carbon material (MoC@C) nanosphere as an ECL super-enhancer and a label of secondary antibody (Ab). MoC@C nanosphere with excellent conductivity and high chemical stability could increase the ECL intensity of the tris-(2,2'-bipyridine)ruthenium (Ru(bpy)). MoC@C/polyethylenimine (MoC@C/PEI) firmly anchored Ab by covalent bonding. Otherwise, amino-modified multiwall carbon nanotubes@nafion (MWCNTs-NH@N) composite film, as substrate material, could connect with the Ru(bpy) by ion exchange and immobilize primary antibodies (Ab) by amide bond. In addition, the boron nitride quantum dots (BNQDs) were utilized as the co-reactant, which were synthesized by using low-cost material melamine as a nitrogen source. Under optimal experimental conditions, the proposed ECL immunosensor possessed a low detection limit of 0.03 pg/mL (S/N = 3) and a wide linear range from 0.1 pg/mL to 50 ng/mL. The ultrasensitive ECL immunosensor had excellent stability, outstanding specificity and great reproducibility. It was also used to detect cTnI in human serum with satisfactory results.
| Reference Key |
wang2019mocbiosensors
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Wang, Luxiao;Xing, Bin;Ren, Xiang;Hu, Xun;Wang, Huan;Wu, Dan;Wei, Qin; |
| Journal | Biosensors & bioelectronics |
| Year | 2019 |
| DOI |
S0956-5663(19)30989-3
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.