High-efficient energy funneling based on electrochemiluminescence resonance energy transfer in graded-gap quantum dots bilayers for immunoassay.
Clicks: 526
ID: 683
2014
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
76.4
/100
526 views
374 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #2 of 194 articles by views in Analytical chemistry
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 194 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
A surprising electrochemiluminescence (ECL) enhancement effect in graded-gap CdSeTe@ZnS-SiO2 quantum dot (QD) bilayers was observed and used to create an ultrasensitive immunoassay. CdSeTe@ZnS-SiO2 QDs of two different sizes were used as a donor-acceptor pair, owing to their tunable energy and low biotoxicity. The graded-gap CdSeTe@ZnS-SiO2 QD bilayers were fabricated by layer-by-layer assembly of differently sized CdSeTe@ZnS-SiO2 QDs on a glutaraldehyde-activated electrode. Benefiting from a short interlayer distance and perfect spectral overlap in the graded-gap QD bilayers, highly efficient ECL resonance energy transfer (ECLRET)-based energy funneling was observed, wherein excitons from trapped states could be effectively recycled. Consequently, the observed ECL enhancement for the bilayers was more than four times greater than that observed for reference samples. The graded-gap QD bilayers were utilized in an ECL biosensor for the detection of carcinoembryonic antigen (CEA). The proposed method featured a detection limit of 0.4 pg mL(-1) CEA with a linear calibration range from 1 pg mL(-1) to 200 ng mL(-1). This method represents a novel approach for versatile detection of biomolecules in research and clinical applications.
| Reference Key |
ji2014high-efficient
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Ji, Jing;He, Li;Shen, Yuanyuan;Hu, Pingping;Li, Xinghua;Jiang, Li-Ping;Zhang, Jian-Rong;Li, Lingling;Zhu, Jun-Jie; |
| Journal | Analytical chemistry |
| Year | 2014 |
| DOI |
10.1021/ac500351d
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.