Individualized cardiac resynchronization therapy: current status
Clicks: 231
ID: 6782
2014
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Popular Article
82.5
/100
231 views
188 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
PopularRanked #182 of 242 articles by views in research reports in clinical cardiology
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 242 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Individualized cardiac resynchronization therapy: current status Martin H Ruwald,1,2 Niels E Bruun1,3 1Department of Cardiology, Gentofte Hospital, Hellerup, Denmark; 2Heart Research Follow-up Program, Division of Cardiology, University of Rochester Medical Center, Rochester, NY, USA; 3Clinical Institute, Aalborg University, Aalborg, Denmark Abstract: Cardiac resynchronization therapy (CRT) has shown a substantial reduction in heart failure patient morbidity and mortality, with improvement in quality of life as well as symptoms. The therapy is, however, limited to approximately 10%–15% of heart failure patients and, typically, 30% do not derive benefit from the device. For optimal outcomes with CRT, the correct selection of patients is of paramount importance. The first parameter is depressed left ventricular systolic function, and the second is a wide QRS complex. Different nuances among clinical trials have rendered guidelines pragmatic and compromising, but also conflicting and confusing. A large proportion of real-life CRTs are implanted in patients where the evidence for benefit is scarce or not present. Further, for optimal benefit, patients require evidence-directed medical therapy at maximal doses, effective placement of ventricular leads, and high biventricular pacing percentages, along with optimized atrioventricular (AV) and interventricular interval device programming. These items, as well as specific clinical characteristics, such as AV block and atrial fibrillation, in the context of CRT indications, are discussed. This review focuses on these issues to guide the clinician through guidelines, with an evidence-based update on the current status of CRT. Keywords: Cardiac resynchronization therapy, prognosis, review, biventricular pacing, guideline, indications
| Reference Key |
martin2014individualizedresearch
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Martin H Ruwald;Niels E Bruun and |
| Journal | research reports in clinical cardiology |
| Year | 2014 |
| DOI |
10.2147/RRCC.S50541
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.