Hemodynamic device-based optimization in cardiac resynchronization therapy: concordance with systematic echocardiographic assessment of AV and VV intervals
Clicks: 283
ID: 6768
2015
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
63.0
/100
283 views
230 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #90 of 242 articles by views in research reports in clinical cardiology
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 242 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Hemodynamic device-based optimization in cardiac resynchronization therapy: concordance with systematic echocardiographic assessment of AV and VV intervals Mário M Oliveira, Luisa M Branco, Ana Galrinho, Nogueira da Silva, Pedro S Cunha, Bruno Valente, Joana Feliciano, Ricardo Pimenta, Ana Sofia Delgado, Rui Cruz Ferreira Santa Marta Hospital, Lisbon, Portugal Background: Inappropriate settings of atrioventricular (AV) and ventriculo-ventricular (VV) intervals can be one of the factors impacting response to cardiac resynchronization therapy (CRT). Optimal concordance of AV and VV intervals between echocardiographic-based assessment and a device-based automatic programming with a hemodynamic sensor was investigated, together with left ventricle (LV) reverse remodeling after 6 months of regular automatic device-based optimization.Methods: We evaluated blindly 30 systematic echocardiographic examinations during 6 months in 17 patients (12 men, 64±10 years, in sinus rhythm and New York Heart Association class III; 76% with non-ischemic dilated cardiomyopathy, LV ejection fraction [LVEF] <35%, QRS 130 milliseconds and LV dyssynchrony) implanted with the SonRtip lead and a cardioverter-defibrillator device. Dyssynchrony (AV, VV, or intraventricular) was evaluated by an experienced operator blinded to the device programming, using conventional echocardiography, tissue synchronization imaging, tissue Doppler imaging, radial strain, and 3D echocardiography.Results: Either no AV or VV dyssynchrony (n
| Reference Key |
mrio2015hemodynamicresearch
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Mário M Oliveira;Luisa M Branco;Ana Galrinho;Nogueira da Silva;Pedro S Cunha;Bruno Valente;Joana Feliciano;Ricardo Pimenta;Ana Sofia Delgado;Rui Cruz Ferreira and |
| Journal | research reports in clinical cardiology |
| Year | 2015 |
| DOI |
10.2147/RRCC.S82540
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.