Nanofibrous poly(vinyl alcohol)/chitosan contained carbonated hydroxyapatite nanoparticles scaffold for bone tissue engineering.

Clicks: 422
ID: 67281
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #16 of 133 articles by views in materials science & engineering c, materials for biological applications

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 133 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
A scaffold that mimics the physicochemical structure of bone at the nanoscale level is an attractive alternative to conventional bone grafts, but its development remains a main challenge in bone tissue engineering today. This work describes the fabrication of a nanofibrous poly(vinyl alcohol)/chitosan/carbonated hydroxyapatite (PVA/CS/CHAp) scaffold. CHAp nanoparticles were synthesized using a co-precipitation method, and nanofibrous PVA/CS/CHAp scaffolds were fabricated by electrospinning using CHAp concentrations of 0, 5, 10, 15, and 20 wt%. The physicochemical properties of the scaffolds were evaluated by SEM, XRD, FTIR, and EDS, and the mechanical properties were determined by tensile strength tests. Swelling behavior, protein adsorption onto the scaffold surfaces, surface biomineralization, and cells viability were also evaluated in vitro. The addition of CHAp to the composite decreased the fiber diameter from ∼160 nm at 0 wt% to ∼139 nm at 15 wt% and great agglomerations were evident at 20 wt%. XRD, FTIR, and EDS showed effective incorporation of CHAp into the nanofibrous structure. This CHAp incorporation significantly increased the modulus of the scaffold at PVA/CS/CHAp 15 wt%, with an average 103.86 MPa, but tensile strength was not significantly altered. However, the elongation at break was decreased as the CHAp concentration increased. Swelling capacity of scaffold increases due to CHAp addition. Protein adsorption onto the scaffold increased 2.3fold at 20 wt% when compared to 0 wt%. The PVA/CS/CHAp 15 wt% showed a better bioactivity when compared to PVA/CS/CHAp 0 wt% after immersion of the scaffolds in a simulated body fluid solution for 7 days. Cell viability and cell morphology results reveal that PVA/CS/CHAp able to facilitate osteoblast cells to attach and proliferate. Introducing higher CHAp into the scaffold could increase the cell viability of the scaffold. PVA/CS/CHAp has potential to serve as an alternative scaffold material for bone tissue engineering.
Reference Key
januariyasa2020nanofibrousmaterials Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Januariyasa, I Komang;Ana, Ika Dewi;Yusuf, Yusril;
Journal materials science & engineering c, materials for biological applications
Year 2020
DOI
S0928-4931(19)31177-4
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.