A point-of-care diagnostics logic detector based on glucose oxidase immobilized lanthanide functionalized metal-organic frameworks.
Clicks: 411
ID: 67270
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
77.1
/100
411 views
284 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #14 of 106 articles by views in Nanoscale
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
In this work, a novel lanthanide functionalized metal organic framework enzyme (L-MOF-enzyme) composite has been first prepared via a surface attachment strategy between Eu3+@UMOF and glucose oxidase (GOx). Here, the Eu3+@UMOF can be used as a support for GOx immobilization and also a responsive fluorescent center towards glucose (Glu). The resulting material not only exhibits fascinating luminescence properties based on the 5D0 → 7F2 transition of Eu3+ and the catalytic performance of enzymes, but also some advantages of MOF-enzyme composites, including better stability, and great fluorescence selectivity and sensitivity towards Glu (detection limit = 0.2 μM). Besides, the composite exhibited an excellent selectivity and sensitivity towards Glu in serum and urine under room temperature and neutral conditions, which breaks the limitation of specific catalytic conditions of enzymes. Taking all the advantages of the L-MOF-enzyme composite, a point-of care (POC) diagnostics logic detector which can be used for the fluorescence detection of Glu in urine is designed. From the three outputs of the logic detector (L, M and H), we can intuitively realize the self-diagnosis of the three ranges of Glu concentrations that act as the inputs of the detector (0.1 μM-10 μM, 10 μM-10 mM, >10 mM) by the naked eye. The logic detector allows us, especially diabetics, to instantly detect glucose levels in the urine without going to the hospital for complicated inspections. This is the first attempt using L-MOFs combined with GOx to construct a POC diagnostics logic detector for fluorescence detection of Glu.
| Reference Key |
zhang2019ananoscale
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Zhang, Yu;Yan, Bing; |
| Journal | Nanoscale |
| Year | 2019 |
| DOI |
10.1039/c9nr06475c
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.