Dye modified metal-organic framework as a recyclable luminescent sensor for nicotine determination in urine solution and living cell.
Clicks: 393
ID: 67269
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
67.0
/100
393 views
263 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #30 of 899 articles by views in ACS applied materials & interfaces
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 899 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
A water-stable and pH-independent sensor for qualitative and quantitative detection of nicotine in urine solution and living cell was successfully developed. This material, named MB@UiO-66-NH2, can be synthesized by encapsulating methylene blue (MB) with a well-known metal-organic framework (MOF) UiO-66-NH2 through a simple impregnation method. The fluorescence intensity of the system was significantly enhanced when a certain amount of nicotine was added. In the meanwhile, MB is reduced by reductive nicotine to form leucomethylene blue (LB). The proposed sensor displayed excellent selectivity and sensitivity toward nicotine with LOD (limit of detection) of 0.98 µM, which is comparable or even better than that of the electrochemistry detecting methods for nicotine. The obvious enhancement and blue shift of the emission arise from the photoinduced electron transfer (PET) from LB to the UiO-66-NH2. The photophysical properties and the sensing applications of MB@UiO-66-NH2 suggest that this composite can be acted as a sensitive, selective, recyclable and fluorogenic sensor for nicotine determination in urine solution and living cell.
| Reference Key |
yan2019dyeacs
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Yan, Dan;Lou, Yuheng;Yang, Yunhui;Chen, Ziao;Cai, Yiping;Guo, Zhiyong;Zhan, Hongbing;Chen, Banglin; |
| Journal | ACS applied materials & interfaces |
| Year | 2019 |
| DOI |
10.1021/acsami.9b17310
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.