Data requirements for applying machine learning to energy disaggregation
Clicks: 207
ID: 67186
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
64.6
/100
207 views
164 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #138 of 220 articles by views in energies
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 220 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Energy disaggregation, or nonintrusive load monitoring (NILM), is a technology for separating a household’s aggregate electricity consumption information. Although this technology was developed in 1992, its practical usage and mass deployment have been rather limited, possibly because the commonly used datasets are not adequate for NILM research. In this study, we report the findings from a newly collected dataset that contains 10 Hz sampling data for 58 houses. The dataset not only contains the aggregate measurements, but also individual appliance measurements for three types of appliances. By applying three classification algorithms (vanilla DNN (Deep Neural Network), ML (Machine Learning) with feature engineering, and CNN (Convolutional Neural Network) with hyper-parameter tuning) and a recent regression algorithm (Subtask Gated Network) to the new dataset, we show that NILM performance can be significantly limited when the data sampling rate is too low or when the number of distinct houses in the dataset is too small. The well-known NILM datasets that are popular in the research community do not meet these requirements. Our results indicate that higher quality datasets should be used to expedite the progress of NILM research.
| Reference Key |
shin2019dataenergies
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Shin, C. |
| Journal | energies |
| Year | 2019 |
| DOI |
10.3390/en12091696
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.