Development of a haptic feedback device to reduce syringe substitution and drug overdosage error.
Clicks: 378
ID: 66370
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
378 views
49 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #7 of 23 articles by views in Anaesthesia
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Despite use of colour-coded labels, syringe substitution (syringe swap) error of anaesthetic drugs remains a frequent and potentially serious cause of iatrogenic harm. We explored the novel concept of using a simple device which can be fitted to existing syringes, and employs colour and raised elements (detents) to provide visual, haptic and auditory cues to supplement the visual cues provided by standard drug labelling, and particularly helps to differentiate, for example, syringes containing vaso-active drugs from other syringes. We produced six different embodiments of the device, and performed a randomised unblinded study with 14 volunteers to identify the functional characteristics which met with the approval of the majority of participants, and the mechanical characteristics which produced adequate haptic feedback without excessive resistance to injection. The optimal design was identified, which required the user to exert a mean (SD) force of ~20 (7) N to overcome the resistance of the detents in the syringe. The majority of volunteers felt that a device of this type would be helpful in reducing the incidence of syringe substitution error; however, further research is needed to assess the efficacy of this innovation in the clinical environment.
| Reference Key |
williams2019developmentanaesthesia
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Williams, D;Eagle, B;Dingley, J; |
| Journal | Anaesthesia |
| Year | 2019 |
| DOI |
10.1111/anae.14736
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.