Blood cleaner on-chip design for artificial human kidney manipulation

Clicks: 246
ID: 6598
2011
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Star

Ranked #133 of 189 articles by views in international journal of nanomedicine

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 189 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Blood cleaner on-chip design for artificial human kidney manipulation N Suwanpayak1, MA Jalil2, MS Aziz3, FD Ismail3, J Ali3, PP Yupapin11Nanoscale Science and Engineering Research Alliance (N'SERA), Advanced Research Center for Photonics, Faculty of Science, King Mongkut's Institute of Technology, Ladkrabang, Bangkok, Thailand; 2Ibnu Sina Institute of Fundamental Science Studies (IIS), 3Institute of Advanced Photonics Science, Nanotechnology Research Alliance, Universiti Teknologi Malaysia, Johor Bahru, MalaysiaAbstract: A novel design of a blood cleaner on-chip using an optical waveguide known as a PANDA ring resonator is proposed. By controlling some suitable parameters, the optical vortices (gradient optical fields/wells) can be generated and used to form the trapping tools in the same way as optical tweezers. In operation, the trapping force is formed by the combination between the gradient field and scattering photons by using the intense optical vortices generated within the PANDA ring resonator. This can be used for blood waste trapping and moves dynamically within the blood cleaner on-chip system (artificial kidney), and is performed within the wavelength routers. Finally, the blood quality test is exploited by the external probe before sending to the destination. The advantage of the proposed kidney on-chip system is that the unwanted substances can be trapped and filtered from the artificial kidney, which can be available for blood cleaning applications.Keywords: optical trapping, blood dialysis, blood cleaner, human kidney manipulation
Reference Key
n2011bloodinternational Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors N Suwanpayak;MA Jalil;MS Aziz;FD Ismail;J Ali;PP Yupapin and
Journal international journal of nanomedicine
Year 2011
DOI
10.2147/IJN.S19077
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.