THE IMPACT ON THE EYE LENS OF RADIATION EMITTED BY NATURAL RADIONUCLIDES (LEAD-210) PRESENT IN RADIATION PROTECTION GLASSES.
Clicks: 393
ID: 65017
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
74.1
/100
393 views
264 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #1 of 43 articles by views in Radiation protection dosimetry
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Most radiation protection items made from modern lead contain 210Pb. This study estimated the impact on eye lens of radiation derived from the 210Pb in three types of radiation protection glasses. The counts from the glasses were measured using a Geiger-Müeller survey meter. The net count rate was 92 ± 1 cpm at a distance of 0.5 cm for one type of glasses. Additionally, we conducted a qualitative γ-ray spectrum analysis using a high-purity germanium semiconductor detector. The absorbed dose in the eye lens was related to 210Pb and its daughter radionuclide, 210Bi; this dose was calculated by applying dose conversion coefficients provided by the International Commission on Radiological Protection. The absorbed dose rate in eye lens was conservatively calculated to be on the order of 10 nGy/h for the type of glasses containing the most 210Pb. The dose from β-rays accounted for >99%. In addition, we investigated the dose-reduction effect using a thin acrylic plate. The count rate approximately decreased to background level by inserting a plate with a thickness of 1 mm. We conclude that the impact of 210Pb contained in radiation protection glasses is negligibly small, particularly considering the usefulness of the significant external exposure reduction.
| Reference Key |
osanai2019theradiation
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Osanai, Minoru;Kudo, Kohsei;Hosoda, Masahiro;Tazoe, Hirofumi;Akata, Naofumi;Kitajima, Maiko;Tsushima, Megumi;Komiya, Nobuhiro;Kudo, Masaya;Tsujiguchi, Takakiyo;Takagi, Masafumi;Hosokawa, Yoichiro;Saito, Yoko; |
| Journal | Radiation protection dosimetry |
| Year | 2019 |
| DOI |
ncz252
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.