Validation of an UHPLC-MS/MS Method for the Determination of Glaucocalyxin A, a Novel Potent Negative Akt Regulator in Rat Plasma, Lung and Brain Tissues: Application to a Pharmacokinetic Study.

Clicks: 402
ID: 65010
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #2 of 14 articles by views in Journal of chromatographic science

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Glaucocalyxin A, a novel potent negative Akt regulator, is a major active constituent of Rabdosia japonica. A simple, specific and sensitive ultra-high pressure liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) method was developed and validated for the quantification of glaucocalyxin A in rat plasma, lung and brain tissues after intravenous administration. Sample preparation was carried out through a simple liqiud-liquid extraction with ethyl acetate using bullatine A as internal standard. The chromatographic separation was achieved by using an Agilent ZORBAX Eclipse Plus C18 column (3.0 mm × 100 mm, 1.8 μm) with a mobile phase of acetonitrile and water containing 0.1% formic acid in a gradient elution. Mass spectrometry analysis was conducted in positive ionization mode with multiple reaction monitoring transitions at m/z 333.2 → 157.1 for glaucocalyxin A and m/z 344.2 → 128.1 for IS. Calibration curves were linear over the ranges of 20.0-4000 ng/mL for both plasma and tissue samples (r2 > 0.99). The Lower limit of quantification (LLOQ) was 0.284 ng/mL. The intra-day and inter-day precision relative standard deviation (RSD%) were <14.9%, while the accuracy ranged from -12.5 to 17.0% for LLOQ and quality control samples. This UHPLC-MS/MS method was successfully applied in the pharmacokinetics, lung and brain tissue distributions of glaucocalyxin A after intravenous administration.
Reference Key
deng2019validationjournal Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Deng, Zhipeng;Liu, Qian;He, Jixiang;Zhang, Sixi;Zhou, Wei;
Journal Journal of chromatographic science
Year 2019
DOI
bmz095
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.