Applicability of the direct injection liquid chromatographic tandem mass spectrometric analytical approach to the sub-ngL determination of perfluoro-alkyl acids in waste, surface, ground and drinking water samples.

Clicks: 349
ID: 64947
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #22 of 391 articles by views in Talanta

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 391 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
The applicability of a direct injection UHPLC-MS/MS method for the analysis of several perfluoroalkyl acids (PFAAs) in a wide range of water matrices was investigated. The method is based on the direct injection of 100µL of centrifuged water sample, without any other sample treatment. Very good method detection limits (0.014-0.44ngL) and excellent intra and inter-day precision (RSD% values in the range 1.8-4.4% and 2.7-5.7%, respectively) were achieved, with a total analysis time of 20min per sample. A high number of samples - i.e. 8 drinking waters (DW), 12 ground waters (GW), 13 surface waters (SW), 8 influents and 11 effluents of wastewater treatment plants (WWTP and WWTP) were processed and the extent of matrix effect (ME) was calculated, highlighting the strong prevalence of |ME| < 20%. The occurrence of |ME| > 50% was occasionally observed only for perfluorooctanesulphonic and perfluorodecanoic acids. Linear discriminant analysis highlighted the great contribution of the sample origin (i.e. DW, GW, SW, WWTP and WWTP) to the ME. Partial least square regression (PLS) and leave-one-out cross-validation were performed in order to interpret and predict the signal suppression or enhancement phenomena as a function of physicochemical parameters of water samples (i.e. conductivity, hardness and chemical oxygen demand) and background chromatographic area. The PLS approach resulted only in an approximate screening, due to the low prediction power of the PLS models. However, for most analytes in most samples, the fitted and cross-validated values were such as to correctly distinguish between | ME | higher than 20% or below this limit. PFAAs in the aforementioned water samples were quantified by means of the standard addition method, highlighting their occurrence mainly in WWTP influents and effluents, at concentrations as high as one hundred of µgL.
Reference Key
ciofi2018applicabilitytalanta Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Ciofi, Lorenzo;Renai, Lapo;Rossini, Daniele;Ancillotti, Claudia;Falai, Alida;Fibbi, Donatella;Bruzzoniti, Maria Concetta;Santana-Rodriguez, José Juan;Orlandini, Serena;Del Bubba, Massimo;
Journal Talanta
Year 2018
DOI
S0039-9140(17)30881-0
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.