Electrophoretic deposition of hydroxyapatite-CaSiO3-chitosan composite coatings.
Clicks: 296
ID: 64755
2009
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Star Article
71.0
/100
296 views
188 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
StarRanked #54 of 128 articles by views in Journal of colloid and interface science
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 128 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Electrophoretic deposition (EPD) method has been developed for the fabrication of hydroxyapatite (HA)-CaSiO(3) (CS)-chitosan composite coatings for biomedical applications. The use of chitosan enabled the co-deposition of HA and CS particles and offered the advantage of room temperature processing of composite materials. The coating composition was varied by the variation of HA and CS concentrations in the chitosan solutions. Cathodic deposits were obtained as HA-CS-chitosan monolayers, HA-chitosan/chitosan multilayers or functionally graded materials (FGM) containing HA-chitosan and CS-chitosan layers of different composition. The thickness of the individual layers was varied in the range of 0.1-20 microm. The deposition yield was studied at different experimental conditions and compared with the results of modeling. It was shown that the moving boundary model for the two component system can explain the non-linear increase in the deposition yield with increasing HA concentration in chitosan solutions. The obtained coatings were studied by thermogravimetric analysis (TGA), differential thermal analysis (DTA) and scanning electron microscopy (SEM). Potentiodynamic polarization and electrochemical impedance spectroscopy (EIS) studies showed that these coatings provided corrosion protection of stainless steel substrates in Ringer's physiological solution. The deposition mechanism and kinetics of deposition have been discussed.
| Reference Key |
pang2009electrophoreticjournal
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Pang, Xin;Casagrande, Travis;Zhitomirsky, Igor; |
| Journal | Journal of colloid and interface science |
| Year | 2009 |
| DOI |
10.1016/j.jcis.2008.10.070
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.