Fluviograph Design Based on an Ultra-Small Pressure Sensor.

Clicks: 282
ID: 64470
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #753 of 1,694 articles by views in sensors

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 1,694 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Groundwater dynamic monitoring of assessment points and evaluation areas has a significant predictive effect for controlling the occurrence of disasters. Obtaining water level and water temperature change data can provide important theoretical significance and reference values. However, in some remote areas of China, the measurement data concerning water level change are mostly obtained by manual measurement. This measurement method not only wastes manpower, but also cannot ensure the accuracy and real-time nature of the data. Therefore, this paper carried out research and design on a fluviograph, based on the relationship between hydraulic pressure and water depth. In the paper, the fluviograph used ultra-small pressure sensors to complete the data acquisition of the water level, a STM32L011 single-chip microcomputer (STMicroelectronics, Geneva, Switzerland) to process the data, and LabVIEW software to display the final data. Additionally, the water level data record and water temperature information record can be fed back to the user and the manager. After laboratory testing, the water level variation error range of this fluviograph was 1-2 cm, and the water temperature error range was less than 1 °C, which indicates the accuracy of the metrical data. The results show that the fluviograph realizes the function of automatically recording the water level and water temperature of the monitoring point, and it improves the social production efficiency greatly.
Reference Key
li2019fluviographsensors Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Li, Shanshan;Duan, Qingming;Chu, Xunyu;Yang, Chao;
Journal sensors
Year 2019
DOI
E4615
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.