Nano volume fractionation strategy for dilute-and-shoot injections in off-line loss-less proteomic workflows for extensive protein identifications of ultra-low sample amounts.

Clicks: 269
ID: 63876
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #38 of 58 articles by views in journal of chromatography a

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
A proteomic workflow for a simple loss-less manual nano-fractionation (300 nL/fraction) for low µg sample amounts which avoids the need to dry down or transfer fractions to autosampler vials is shown to be feasible. It is demonstrated that the conventional procedure of drying samples down followed by reconstitution negatively affects the number of protein and peptide identifications. Furthermore, these losses seem to disproportionately affect hydrophobic peptides from the drying down and reconstitution step. By collecting and concatenating the fractions while the outlet of the column is submerged in a small predefined volume of 0.2% formic acid, the content of acetonitrile in the collecting vials was lowered such that it was compatible with direct injection for the online analysis. This additionally resulted in a time gain of approx. an hour for the total fractionation time. Acetonitrile concentrations up to 7.5% do not seem to compromise the chromatographic performance in the online analysis. Using as little as 2 µg digested HeLa lysate, approx. 7000 protein groups could be easily identified with 2 or more unique peptides. This was the case when fractionation was performed at pH 10 as well as at pH 5.5.
Reference Key
reubsaet2019nanojournal Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Reubsaet, Léon;Sweredoski, Michael J;Moradian, Annie;Lomenick, Brett;Eggleston-Rangel, Roxana;Garbis, Spiros D;