Test-retest reliability, concurrent validity and correlates of the two-minute walk test in outpatients with psychosis.
Clicks: 424
ID: 63444
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
424 views
40 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #4 of 101 articles by views in psychiatry research
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
The aim of this study was to investigate the test-retest reliability of the 2-minute walk test (2MWT) and the concurrent validity with the 6-minute walk test (6MWT) in outpatients with psychosis. We also explored whether there was a practice effect, determined minimal detectable changes (MDC) and assessed which factors are associated with the 2MWT performance. Fifty outpatients [22 women; 33.5 (14.3) years] performed the 2MWT twice and the 6MWT once and completed the Simple Physical Activity Questionnaire (SIMPAQ) and Brief Symptoms Inventory -18. The median (interquartile) 2MWT score on the first and second test were 128.0 (44.0) meters and 128.0 (31.5) meters, without significant difference between the two trials. The intraclass coefficient was 0.94 (95% confidence interval=0.91-0.97). The significant Spearman Rho correlation between the second 2MWT and the 6MWT was 0.69. The MDC was 22 m for men and 21 m for women. There was no evidence for a practice effect. Variability in SIMPAQ sedentary, exercise, incidental physical activity and leg pain following the test explained 54.6% of the variance in 2MWT score. The current study demonstrates that the 2MWT is a reliable, valid and clinically feasible tool for assessing and evaluating the functional exercise capacity in outpatients with psychosis.
| Reference Key |
vancampfort2019testretestpsychiatry
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Vancampfort, Davy;Kimbowa, Samuel;Basangwa, David;Smith, Lee;Stubbs, Brendon;Van Damme, Tine;De Hert, Marc;Mugisha, James; |
| Journal | psychiatry research |
| Year | 2019 |
| DOI |
S0165-1781(19)31492-1
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.