Cryptographic Considerations for Automation and SCADA Systems Using Trusted Platform Modules.
Clicks: 384
ID: 63314
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
70.1
/100
384 views
263 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #114 of 1,694 articles by views in sensors
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 1,694 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
The increased number of cyber threats against the Supervisory Control and Data Acquisition (SCADA) and automation systems in the Industrial-Internet-of-Things (IIoT) and Industry 4.0 era has raised concerns in respect to the importance of securing critical infrastructures and manufacturing plants. The evolution towards interconnection and interoperability has expanded the vulnerabilities of these systems, especially in the context of the widely spread legacy standard protocols, by exposing the data to the outside network. After gaining access to the system data by launching a variety of attacks, an intruder can cause severe damage to the industrial process in place. Hence, this paper attempts to respond to the security issue caused by legacy structures using insecure communication protocols (e.g., Modbus TCP, DNP3, S7), presenting a different perspective focused on the capabilities of a trusted platform module (TPM). Furthermore, the intent is to assure the authenticity of the data transmitted between two entities on the same (horizontal interoperation) or different (vertical interoperation) hierarchical levels communicating through Modbus TCP protocol based on functionalities obtained by integrating trusted platform modules. From the experimental results perspective, the paper aims to show the advantages of integrating TPMs in automation/SCADA systems in terms of security. Two methods are proposed in order to assure the authenticity of the messages which are transmitted, respectively the study presents the measurements related to the increased time latency introduced due to the proposed concept.
| Reference Key |
tidrea2019cryptographicsensors
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Tidrea, Alexandra;Korodi, Adrian;Silea, Ioan; |
| Journal | sensors |
| Year | 2019 |
| DOI |
E4191
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.