Reduction of turnaround time for non-tuberculous mycobacteria detection in heater-cooler units by propidium monoazide real-time PCR.
Clicks: 401
ID: 61990
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
401 views
31 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #9 of 25 articles by views in The Journal of hospital infection
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Invasive non-tuberculous mycobacteria (NTM) infections are emerging worldwide in patients undergoing open-chest cardiac bypass surgery exposed to contaminated heater-cooler units (HCUs). Although this outbreak has been investigated by culturing bacteria isolated from HCU aerosol and water samples, these conventional methods have low-analytic sensitivity, high rates of sample contamination and long turnaround time (TAT).To develop a simple and effective method to detect NTM in HCUs by real-time PCR, with a short laboratory TAT and reliable culture results.A total of 281 water samples collected from various HCUs at 7 Italian hospitals were simultaneously screened for NTM by a propidium monoazide (PMA)-PCR assay and by conventional culture testing. The results were analyzed with culture testing being the reference method.i) The agreement between culture testing and PMA-PCR was 85.0% with a Ct cut-off value of < 38 vs.80.0% with a Ct of < 43, with a moderate Cohen's kappa coefficient; ii) the Ct cut-off value of < 42 was deemed more suitable for predicting positive specimens; iii) given the low concentration of target DNA in water samples, the minimum volume to be tested was 1 lt.We highly recommend the use of PMA-PCR for fast detection of NTM from environmental samples in order to ascertain whether HCUs may represent a potential source of human exposure to NTM. This reliable and simple method reduces laboratory TAT compared to conventional methods (1-2 days vs. 8 weeks, respectively), thereby improving control strategies and effective management of HCUs.
| Reference Key |
ditommaso2019reductionthe
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Ditommaso, Savina;Giacomuzzi, Monica;Memoli, Gabriele;Cavallo, Rossana;Curtoni, Antonio;Avolio, Maria;Silvestre, Carlo;Zotti, Carla M; |
| Journal | The Journal of hospital infection |
| Year | 2019 |
| DOI |
S0195-6701(19)30445-1
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.