Optical Coherence Tomography Observation of Gonio Structures during Microhook Ab Interno Trabeculotomy
Clicks: 387
ID: 61850
2017
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.3
/100
387 views
32 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #3 of 7 articles by views in journal of ophthalmology
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Introduction. Intraoperative observation of ocular structures using microscope-integrated optical coherence tomography (iOCT) has been adopted recently. I report my initial feasibility assessment of iOCT for the incised trabecular meshwork observation during microhook ab interno trabeculotomy. Case Series. Both the nasal and temporal sides or either side of the trabecular meshwork/inner wall of Schlemm’s canal was incised more than 3 clock hours. After then, under observation using a Swan-Jacob gonioprism lens with the real-time 5-line scan mode, OCT images of the area were successfully acquired in 10 (83%) of 12 sides in nine eyes. Based on the appearance of the acquired images of the 10 sides, the trabeculotomy cleft could be classified into three incisional patterns, that is, six (60%) anterior-opening patterns (posterior-based flap), three (30%) middle-opening patterns (posterior- and anterior-based flaps), and one (10%) posterior-opening pattern (anterior-based flap), according to the predominant locations of the trabecular meshwork flaps. Conclusion. Intraoperative observation of the gonio structures including the trabeculotomy cleft was feasible using the RESCAN 700 in combination with a gonioprism.
| Reference Key |
tanito2017opticaljournal
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Tanito, Masaki; |
| Journal | journal of ophthalmology |
| Year | 2017 |
| DOI |
DOI not found
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments