Synthesis of carbon quantum dots-doped dummy molecularly imprinted polymer monolithic column for selective enrichment and analysis of aflatoxin B in peanut.
Clicks: 358
ID: 60915
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
79.6
/100
358 views
243 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #17 of 235 articles by views in Journal of pharmaceutical and biomedical analysis
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 235 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
In this study, a novel method was proposed to sensitively determine aflatoxin B (AFB) in peanut sample by using a carbon quantum dots-coated dummy molecularly imprinted polymer (CDs-DMIP) monolithic column for pretreatment coupled with high performance liquid chromatography-fluorescence detection (HPLC-FLD). The CDs-DMIP monolithic column was prepared by in-situ polymerization in a water bath using 5,7-dimethoxycoumarin as dummy template molecule. The CDs-DMIP monolithic column was applied to determine AFB by HPLC-FLD. Satisfactory linearity was obtained over 0.5-2000ngmL, with a high correlation coefficient of 0.9999. The recoveries of AFB in peanut sample ranged from 79.5% to 91.2%, and the intraday and interday relative standard deviation ranged from 1.2% to 4.9%. Limit of detection (S/N=3) and limit of quantitation (S/N=10) were 0.118ngmL and 0.393ngmL, respectively. Under the optimized conditions, the enrichment factor was over 71-fold. AFB in peanut sample and even some other samples could be sensitively determined by CDs-DMIP-HPLC-FLD method.
| Reference Key |
liang2018synthesisjournal
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Liang, Guohuan;Zhai, Haiyun;Huang, Lu;Tan, Xuecai;Zhou, Qing;Yu, Xiao;Lin, Haidan; |
| Journal | Journal of pharmaceutical and biomedical analysis |
| Year | 2018 |
| DOI |
S0731-7085(17)31931-3
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.