A fluorescent lateral flow biosensor for the quantitative detection of Vaspin using upconverting nanoparticles.

Clicks: 274
ID: 60788
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #66 of 116 articles by views in spectrochimica acta part a, molecular and biomolecular spectroscopy

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Vaspin is a protein present in human serum that can cause type-2 diabetes, obesity, and other cardiovascular diseases. We report fluorescent upconverting nanoparticles (UCNPs)-based lateral flow biosensor for ultrasensitive detection of Vaspin. A pair (primary and secondary) of cognate aptamers was used that has duo binding with Vaspin. UCNPs with a diameter of around 100 nm were used as a tag to label a detection probe (secondary aptamer). A primary aptamer (capture probe) was immobilized on the test zone. Sandwich type hybridization reactions among the conjugate probe, target Vaspin, and primary aptamer were performed on the lateral flow biosensor. In the presence of target Vaspin, UCNPs were captured on the test zone of the biosensor and the fluorescent intensity of the captured UCNPs was measured through a colorimetric app under NIR. Fluorescence intensity indicates the quantity of Vaspin present in the sample. A range of Vaspin concentration across 0.1-55 ng ml with a Limit of detection (LOD) 39 pg ml was tested through this UCNPs based LFSA with high sensitivity, reproducibility and repeatability, whereas it's actual range in human blood is from 0.1 to 7 ng ml. Therefore, this research provides a well-suited lateral flow strip with an ultrasensitive and low-cost approach for the early diagnosis of type-2 diabetes and this could be applied to any targets with a duo of aptamers generated.
Reference Key
ali2019aspectrochimica Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Ali, Muhsin;Sajid, Memoon;Khalid, Muhammad Asad Ullah;Kim, Soo Wan;Lim, Jong Hwan;Huh, Dongeun;Choi, Kyung Hyun;
Journal spectrochimica acta part a, molecular and biomolecular spectroscopy
Year 2019
DOI
S1386-1425(19)31000-5
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.