Referenceless multi-channel signal combination: A demonstration in chemical-shift-encoded water-fat imaging.

Clicks: 375
ID: 60768
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #2 of 13 articles by views in Magnetic resonance in medicine

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Without explicit coil sensitivity information acquired by means of a reference body coil, multi-channel signal combination for water-fat separation (WFS) can be challenging due to channel-dependent phase offsets and chemical-shift dependent phase shifts. This study aims to develop a referenceless, robust, accurate, and fast channel combination method for WFS.A dual-step multi-channel combination method is proposed. In the first step, channel-dependent phase offsets are estimated with a preliminary WFS estimation. In the second step, the multi-channel data are combined after removing phase offsets. Thereafter, WFS is performed to obtain final results. Numerical simulations (4-64 coils) and in vivo experiments (8, 16, 28 coils) at 3T field strength are conducted to compare the proposed method to previous methods. Channel combination with a body-coil scan serves as the reference for in vivo experiments.The proposed method estimates channel-dependent phase offsets accurately. It shows improved robustness to phase singularities than weighted mean and adaptive reconstruction. It is faster than adaptive reconstruction (e.g., 25.45 versus 46.34 s with 28 coils) and the channel-by-channel WFS method (e.g., 21.77 versus 50.04 s with 8 coils). It provides comparable fat quantification accuracy to the reference under various reasonable signal-to-noise ratio conditions (e.g., Pearson correlation coefficient r = 0.981 with P < 0.01, for in vivo fat fractions using flip angle = 10°).The proposed referenceless channel combination method may be beneficial to both qualitative and quantitative water-fat imaging.
Reference Key
liu2019referencelessmagnetic Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Liu, Simin;Wu, Peng;Liu, Haining;Hu, Zhangxuan;Guo, Hua;
Journal Magnetic resonance in medicine
Year 2019
DOI
10.1002/mrm.28028
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.