Referenceless multi-channel signal combination: A demonstration in chemical-shift-encoded water-fat imaging.

Clicks: 410
ID: 60768
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #3 of 13 articles by views in Magnetic resonance in medicine

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Without explicit coil sensitivity information acquired by means of a reference body coil, multi-channel signal combination for water-fat separation (WFS) can be challenging due to channel-dependent phase offsets and chemical-shift dependent phase shifts. This study aims to develop a referenceless, robust, accurate, and fast channel combination method for WFS.A dual-step multi-channel combination method is proposed. In the first step, channel-dependent phase offsets are estimated with a preliminary WFS estimation. In the second step, the multi-channel data are combined after removing phase offsets. Thereafter, WFS is performed to obtain final results. Numerical simulations (4-64 coils) and in vivo experiments (8, 16, 28 coils) at 3T field strength are conducted to compare the proposed method to previous methods. Channel combination with a body-coil scan serves as the reference for in vivo experiments.The proposed method estimates channel-dependent phase offsets accurately. It shows improved robustness to phase singularities than weighted mean and adaptive reconstruction. It is faster than adaptive reconstruction (e.g., 25.45 versus 46.34 s with 28 coils) and the channel-by-channel WFS method (e.g., 21.77 versus 50.04 s with 8 coils). It provides comparable fat quantification accuracy to the reference under various reasonable signal-to-noise ratio conditions (e.g., Pearson correlation coefficient r = 0.981 with P < 0.01, for in vivo fat fractions using flip angle = 10°).The proposed referenceless channel combination method may be beneficial to both qualitative and quantitative water-fat imaging.
Reference Key
liu2019referencelessmagnetic Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal Magnetic resonance in medicine
Year 2019
DOI
10.1002/mrm.28028
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.