Plasmon-Enhanced Electrochemiluminescence of Silver Nanoclusters for microRNA Detection.
Clicks: 378
ID: 60678
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
81.4
/100
378 views
261 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #4 of 42 articles by views in ACS sensors
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Surface plasmon-enhanced electrochemiluminescence (SPEECL) with excellent sensitivity and simplicity has attracted increasing attention. In this work, we reported a novel SPEECL with DNA templated silver nanoclusters (DNA-AgNCs) as ECL emitters and gold nanoparticles (AuNPs) as localized surface plasmon resonance (LSPR) source. The SPEECL with DNA-AgNCs as ECL luminophores possessed low toxicity and avoided the labeling process, which is favorable for its further sensing application. In addition, by investigation of the SPEECL under different distances between DNA-AgNCs and AuNPs, it was demonstrated that the SPEECL was distance dependent. Meanwhile, the SPEECL intensity changed with the sizes and interdistance of AuNPs under different electrodeposition time. Furthermore, by the combination of a cyclic amplification process with enzyme-free catalytic hairpin DNA, a sensitive SPEECL biosensor was proposed for the detection of microRNA (miRNA-21) successfully with a wide linear range from 1 aM to 10 fM and a relatively low detection limit of 0.96 aM, which was applied in the detection of miRNA-21 in real samples with satisfying results. This novel, simple, sensitive, and selective SPEECL with label-free and low-toxic ECL emitters displayed a great potential for bioassay application.
| Reference Key |
feng2019plasmonenhancedacs
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Feng, Xiuyun;Han, Ting;Xiong, Yunfang;Wang, Sicheng;Dai, Tianyue;Chen, Jihua;Zhang, Xiaojun;Wang, Guangfeng; |
| Journal | ACS sensors |
| Year | 2019 |
| DOI |
10.1021/acssensors.9b00413
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.