Plug and play self-configurable IoT gateway node for telemonitoring of ECG.
Clicks: 415
ID: 60485
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
67.5
/100
415 views
275 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #5 of 87 articles by views in Computers in biology and medicine
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
In the era of IoT and hyperconnection, an efficient electrocardiogram (ECG) telemonitoring system in wireless body area network (WBAN) demands an easy to use, self-configurable, secure, plug and play system with minimum hardware and computational complexities. The compression and quantization parameters required for an efficient representation of ECG signal will vary from patient to patient, from lead to lead, and from time to time. To this end, we propose a compressed sensing based WBAN with self-configurable gateway node (CS-SCGN) using deterministic binary block diagonal (DBBD) measurement matrix. The self-configurability is brought in through a low complex method for adaptive tuning of parameters with a careful choice of measurement matrix and data length. The redundant data transfer between sensor nodes and gateway node is avoided by addressing the diverse requirements in ECG remote health monitoring through three modes of configuration in the proposed system. A further reduction in communication and storage cost is achieved by optimizing the number of bits transmitted by sensor nodes by automatically tuning the compression ratio and quantization depth based on the dynamics of ECG signal. The self-configuration algorithm is designed to run at the gateway node in such a way as to optimize the power efficiency of sensor nodes without causing an extra power drain at the gateway node. Also, we investigate the feasibility of using smartphone as an IoT gateway node for performing primary processing to provide local utility before sending the received data to the remote server. The energy efficiency and real-time feasibility of the proposed algorithm are evaluated by implementing the gateway node on Odroid-XU4 board which runs on the same processor as in the latest smartphones. The experimental results indicate that our proposed self-configurable system at the gateway node makes the entire ECG telemonitoring system flexible, plug and play, patient independent and power-efficient.
| Reference Key |
koya2019plugcomputers
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Koya, Aneesh M;Deepthi, P P; |
| Journal | Computers in biology and medicine |
| Year | 2019 |
| DOI |
S0010-4825(19)30236-7
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.