[Thrombolysis by staphylokinase in rabbits with experimental pulmonary embolus].
Clicks: 318
ID: 60024
1998
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Star Article
30.0
/100
318 views
25 readers
AI Quality Assessment
Not analyzed
Readership in this journal
StarRanked #2 of 11 articles by views in yao xue xue bao = acta pharmaceutica sinica
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Thrombolysis effect of recombinant staphylokinase (rSaK) developed in China was evaluated in rabbits with experimental pulmonary embolus model. 125I-labeled human fibrin blood clot was prepared in vitro and was injected through jugular vein resulting in a pulmonary embolus. Twenty thousands AU.kg-1(rSaK-H) or 5000 AU.kg-1(rSaK-L) of rSaK was infused in 0.5 h at constant rate by a peristaltic 20,000 U.kg-1. Another 20,000 AU.kg-1 of rSaK was infused within 2.5 h(rSaK-2.5 h). The residual labeled blood clot in lungs were found to be 62% +/- 11% (rSaK-H), 78% +/- 7% (rSaK-L), 92% +/- 7% (NS), 60% +/- 13% (SK), and 64% +/- 16% (rSaK-2.5 h). 125I-labeled degradation products in blood and urine were also statistically higher in thrombolytic agents treated group than those in NS controls. The results suggest that the thrombolytic effect of rSaK was determined by total dose and not determined by infusion time. Two of seven rabbits in the rSaK 2.5 h infusion group, the bleeding time was prolonged to more than 10 minutes while no prolongation was seen in rSaK high dose group. The clot lysis curves were very similar in 0.5 h or 2.5 h treatment of rSAK in vitro. Michaelis-Menten kinetics studies in vitro revealed that the Kms of rSaK and SK were almost the same, while a higher maximal velocity(34 kBq.min-1) was observed in rSaK than that in SK (10 kBq.min-1).
| Reference Key |
liu1998thrombolysisyao
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Liu, X;Tang, Z;Liang, X;Ma, X;Chen, W; |
| Journal | yao xue xue bao = acta pharmaceutica sinica |
| Year | 1998 |
| DOI |
DOI not found
|
| URL | URL not found |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.