Injection Compression Molded Microlens Arrays for Hyperspectral Imaging.
Clicks: 349
ID: 59833
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
349 views
48 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #18 of 128 articles by views in micromachines
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 128 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
In this work, a polymer microlens array (MLA) for a hyperspectral imaging (HSI) system is produced by means of ultraprecision milling (UP-milling) and injection compression molding. Due to the large number of over 12,000 microlenses on less than 2 cm², the fabrication process is challenging and requires full process control. The study evaluates the process chain and optimizes the single process steps to achieve high quality polymer MLAs. Furthermore, design elements like mounting features are included to facilitate the integration into the final HSI system. The mold insert was produced using ultraprecision milling with a diamond cutting tool. The machining time was optimized to avoid temperature drifts and enable high accuracy. Therefore, single immersions of the diamond tool at a defined angle was used to fabricate each microlens. The MLAs were replicated using injection compression molding. For this process, an injection compression molding tool with moveable frame plate was designed and fabricated. The structured mold insert was used to generate the compression movement, resulting in a homogeneous pressure distribution. The characterization of the MLAs showed high form accuracy of the microlenses and the mounting features. The functionality of the molded optical part could be demonstrated in an HIS system by focusing light spectrums onto a CCD image sensor.
| Reference Key |
roeder2018injectionmicromachines
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Roeder, Marcel;Drexler, Marc;Rothermel, Thilo;Meissner, Thomas;Guenther, Thomas;Zimmermann, André; |
| Journal | micromachines |
| Year | 2018 |
| DOI |
E355
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.