Sensitive amperometric biosensors for detection of glucose and cholesterol using a platinum/reduced graphene oxide/poly(3-aminobenzoic acid) film-modified screen-printed carbon electrode.
Clicks: 412
ID: 59805
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
67.9
/100
412 views
279 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #1 of 14 articles by views in Bioelectrochemistry (Amsterdam, Netherlands)
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
A facile one-step electrochemical synthesis of a platinum/reduced graphene oxide/poly(3-aminobenzoic acid) (Pt/rGO/P3ABA) nanocomposite film on a screen-printed carbon electrode (SPCE) and its application in the development of sensitive amperometric biosensors was successfully demonstrated herein. The electropolymerization of P3ABA together with co-electrodeposition of rGO and Pt was conducted by cyclic voltammetry, as was the GO reduction to rGO. A Pt/rGO/P3ABA-modified SPCE exhibited excellent electrocatalytic oxidation towards hydrogen peroxide (HO) and can be employed as an electrochemical platform for the immobilization of glucose oxidase (GOx) and cholesterol oxidase (ChOx) to fabricate glucose and cholesterol biosensors, respectively. Under the optimized conditions at a working potential of +0.50 V, the proposed biosensors revealed excellent linear responses to glucose and cholesterol in the concentration ranges of 0.25-6.00 mM and 0.25-4.00 mM, respectively, with high sensitivities of 22.01 and 15.94 μA mM cm and low detection limits (LODs) of 44.3 and 40.5 μM. Additionally, the Michaelis-Menten constant (K) of GOx was 3.54 mM, while the K of ChOx was 3.82 mM. Both biosensors displayed a good anti-interference ability and clearly exhibited acceptable recoveries for the detection of glucose and cholesterol in a human serum sample (98.2-104.1%).
| Reference Key |
phetsang2019sensitivebioelectrochemistry
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Phetsang, Sopit;Jakmunee, Jaroon;Mungkornasawakul, Pitchaya;Laocharoensuk, Rawiwan;Ounnunkad, Kontad; |
| Journal | Bioelectrochemistry (Amsterdam, Netherlands) |
| Year | 2019 |
| DOI |
S1567-5394(18)30509-7
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.