Speeding up in vitro Discovery of Structure-Switching Aptamers via Magnetic Cross-Linking Precipitation.
Clicks: 470
ID: 59775
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
67.9
/100
470 views
319 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #3 of 194 articles by views in Analytical chemistry
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 194 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
We report here a modified aptamer selection method, magnetic cross-linking precipitation (MCP)-SELEX, for highly efficient library enrichment and aptamer isolation. MCP-SELEX isolates bound aptamers via highly efficient chemical cross-linking between amino groups of target proteins and activated carboxylic acid groups on magnetic beads (> 90% coupling efficiency). Importantly, MCP-SELEX avoids surface interferences in conventional target-fixed methods and substantially minimizes nonspecific binding. The enrichment efficiencies of MCP-SELEX for various proteins (PD-L1, ubiquitin, thrombin, and HSA) were all greatly higher than those of the conventional target-bound magnetic bead based-SELEX (MB-SELEX). Anti-thrombin aptamer with KD of 33 nM was successfully isolated by four rounds of MCP-SELEX. MCP-SELEX also enabled the efficient aptamer isolation by coupling with MB-SELEX or falling-off-SELEX. We identified structure-switching aptamers (SSAs) that specifically bind to HSA with low nanomolar dissociation constant via 3 rounds of MCP-SELEX and 1 round of falling-off-SELEX. Our HSA SSAs also have ~ 3-fold higher specificity against streptavidin relative to thrombin SSAs discovered through falling-off-SELEX only. The enriched library has ~78-fold higher signal-to-noise ratio (the number of DNAs eluted by 50 nM HSA divided by the number of DNAs self-dissociated in blank buffer) than that obtained by 4 rounds of direct falling-off-SELEX. We finally demonstrated the application of the selected SSA in fluorescent detection of HSA in urine with diagnostic required sensitivity and dynamic range. We expect that MCP-SELEX may be coupled with other selection methods to substantially accelerate aptamer discovery.
| Reference Key |
qiao2019speedinganalytical
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Qiao, Na;Li, Jing;Wu, Xiao;Diao, Donglin;Zhao, Jiaxing;Li, Jiyuan;Ren, Xijiao;Ding, Xiaofan;Shangguan, Dihua;Lou, Xinhui; |
| Journal | Analytical chemistry |
| Year | 2019 |
| DOI |
10.1021/acs.analchem.9b00081
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.