Immunochromatographic assay for ultrasensitive detection of aflatoxin B₁ in maize by highly luminescent quantum dot beads.
Clicks: 358
ID: 59371
2014
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
77.4
/100
358 views
236 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #65 of 899 articles by views in ACS applied materials & interfaces
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 899 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Highly luminescent quantum dot beads (QBs) were synthesized by encapsulating CdSe/ZnS and used for the first time as immunochromatographic assay (ICA) signal amplification probe for ultrasensitive detection of aflatoxin B1 (AFB1) in maize. The challenges to using high brightness QBs as probes for ICA are smooth flow of QBs and nonspecific binding on nitrocellulose (NC) membrane, which are overcome by unique polymer encapsulation of quantum dots (QDs) and surface blocking method. Under optimal conditions, the QB-based ICA (QB-ICA) sensor exhibited dynamic linear detection of AFB1 in maize extract from 5 to 60 pg mL(-1), with a median inhibitory concentration (IC50) of 13.87 ± 0.16 pg mL(-1), that is significantly (39-fold) lower than those of the QD as a signal probe (IC50 = 0.54 ± 0.06 ng mL(-1)). The limit of detection (LOD) for AFB1 using QB-ICA sensor was 0.42 pg mL(-1) in maize extract, which is approximately 2 orders of magnitude better than those of previously reported gold nanoparticle based immunochromatographic assay (AuNP-ICA) and is even comparable with or better than the conventional enzyme-linked immunosorbent assay (ELISA) method. The performance and practicability of our QB-ICA sensor were validated with a commercial ELISA kit and further confirmed with liquid chromatography tandem mass spectrometry (LC-MS/MS). Given its efficient signal amplification performance, the proposed QB-ICA offers great potential for rapid, sensitive, and cost-effective quantitative detection of analytes in food safety monitoring.
| Reference Key |
ren2014immunochromatographicacs
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Ren, Meiling;Xu, Hengyi;Huang, Xiaolin;Kuang, Min;Xiong, Yonghua;Xu, Hong;Xu, Yang;Chen, Hongyu;Wang, Andrew; |
| Journal | ACS applied materials & interfaces |
| Year | 2014 |
| DOI |
10.1021/am503517s
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.