"Multistage in one touch" design with a universal labelling conjugate for high-sensitive lateral flow immunoassays.

Clicks: 324
ID: 59368
2016
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #27 of 85 articles by views in Biosensors & bioelectronics

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Immunoreagents with good results in the competitive enzyme-linked immunosorbent assay are often unable to provide the required detection limit in the traditional competitive immunochromatographic assay. The solution may be either the production of new reagents or improving the test strip. In the latter case, the assay is often performed stepwise using additional liquid reagents, but this is a significant drawback for practical use. We introduce a test strip made as a dry chemical device that still provides the two-step immunochemical interactions - formation of a complex of specific antibodies with an antigen and its detection by a conjugate of antispecies antibodies with a nano-sized label. Analysis with this test strip is similar to that with ordinary test strips and requires no additional reagents and manipulation. The use of specific antibodies and marker as two separate components allows to improve the analytical parameters. The new test significantly lowers the limit of detection, making it possible to use antibodies previously ineffective in immunochromatography. The proposed approach was tested by determining zearalenone and aflatoxin B1 mycotoxins. The visual limit of detection for aflatoxin B1 decreased to 0.6ng/mL compared to 11ng/mL with an ordinary test strip. For zearalenone, a test strip was created with visual detection limit of 6ng/mL with reagents inefficient in the traditional test strip (which is not able to detect even 9μg/mL of zearalenone). Thus, the proposed approach allows obtaining 'dry', multi-stage, immunochromatographic test strips, providing a highly sensitive detection method.
Reference Key
urusov2016multistagebiosensors Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Urusov, Alexandr E;Petrakova, Alina V;Zherdev, Anatoly V;Dzantiev, Boris B;
Journal Biosensors & bioelectronics
Year 2016
DOI
S0956-5663(16)30656-X
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.